• Title of article

    Performance of SRRC 1.3 GeV electron booster synchrotron

  • Author/Authors

    Lin، نويسنده , , K.K and Hsu، نويسنده , , K.T and Ueng، نويسنده , , T.S. and Chiou، نويسنده , , J.P. and Hwang، نويسنده , , J.I and Liu، نويسنده , , Y.C and Modeer، نويسنده , , J، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    12
  • From page
    1
  • To page
    12
  • Abstract
    The characteristics and the performance of SRRC 1.3 GeV electron booster synchrotron are described in this report. Operation parameters, such as synchrotron tune, betatron tune, momentum compaction factor, betatron function, chromaticity etc. were measured at injection energy, 50 MeV, DC mode; and compared with calculated results at a tune of vx = 4.40, vy = 2.43. The tune drift and the bunch length variation of accelerated beam have been studied. The energy spread and the beam emittance variation during ramping were derived. The diagnostics instrumentation used in this experiment was described. Comparison between experimental results and theoretical expectations is presented.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1995
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    1994967