Author/Authors :
Kharitonov، نويسنده , , Yu.P. and Golovchenko، نويسنده , , A.N. and Mikheev، نويسنده , , V.L. and Ponomarenko، نويسنده , , V.A. and Timokhin، نويسنده , , S.N. and Tretyakova، نويسنده , , S.P. and Yakushev، نويسنده , , A.B.، نويسنده ,
Abstract :
Experimental results of collecting recoil atoms produced in reactions with heavy ions are presented. The recoil atoms thermalized in gas are transported by the gas flow into a 1 mm wide slit channel formed by the sensitive surfaces of radioactive decay detectors. Due to the adsorption from the gas flow it is possible to collect ≥50% of the initial recoil atoms on the detector surfaces within a time interval of ≤0.1 s.