Author/Authors :
Colledani، نويسنده , , C. and Dulinski، نويسنده , , W. and Turchetta، نويسنده , , R. and Djama، نويسنده , , Albis F. and Rudge، نويسنده , , A. and Weilhammer، نويسنده , , P.، نويسنده ,
Abstract :
A precise and compact silicon microstrip detector telescope designed to provide reference information for charged particle tracks has been constructed. First operation results are presented. A signal over noise ratio higher than 100 has been obtained, resulting in a spatial resolution of 1.4 μm per detector, for a readout pitch of 50 μm. At a position in the center of the telescope, a track extrapolation error of 0.7 μm can be obtained for reconstructed tracks.