Title of article :
The photomultiplier tube testing facility for the Sudbury Neutrino Observatory
Author/Authors :
Jillings، نويسنده , , C.J and Ford، نويسنده , , R.J and Hallin، نويسنده , , A.L and Harvey، نويسنده , , P.J and MacLeod، نويسنده , , R.W and Mak، نويسنده , , H.B and Skensved، نويسنده , , P and Stevenson، نويسنده , , R.L، نويسنده ,
Pages :
9
From page :
421
To page :
429
Abstract :
A facility to test the photomultiplier tubes (PMTs) for the Sudbury Neutrino Observatory (SNO) was constructed at Queenʹs University. The facility measured the noise rate, relative efficiency, and charge and time spectra of single photoelectron anode signals for 44 PMTs daily. The system is described, and detailed results of the testing for two particular PMTs are presented as well as statistics for 9829 Hamamatsu R1408 PMTs accepted for use in SNO.
Journal title :
Astroparticle Physics
Record number :
1997926
Link To Document :
بازگشت