• Title of article

    Application of neutron radiography to a diagnosis of refrigerator

  • Author/Authors

    Asano، نويسنده , , H. and Takenaka، نويسنده , , N. and Fujii، نويسنده , , T. and Murata، نويسنده , , Y. and Mochiki، نويسنده , , K. and Taguchi، نويسنده , , A. and Matsubayashi، نويسنده , , M. and Tsuruno، نويسنده , , A.، نويسنده ,

  • Pages
    4
  • From page
    170
  • To page
    173
  • Abstract
    A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized.
  • Keywords
    two-phase flows , Refrigerator , Diagnosis of practical machine , Real-time , Cooled CCD camera
  • Journal title
    Astroparticle Physics
  • Record number

    1998530