Title of article
Performance of MSGC with analog pipeline readout
Author/Authors
Gَmez، نويسنده , , F. and Adeva، نويسنده , , B. and Gracia، نويسنده , , G. and Lَpez، نويسنده , , M.A. and Nٌْez، نويسنده , , T. and Pazos، نويسنده , , A. and Plَ، نويسنده , , M. and Rodrيguez، نويسنده , , A. and Santamarina، نويسنده , , C. and Vلzquez، نويسنده , , P.، نويسنده ,
Pages
9
From page
351
To page
359
Abstract
We analyse some of the performance characteristics of a chromium MSGC operated with Ar-DME 50%-50% in a test beam at CERN. Excellent signal-to-noise ratio and efficiency has been achieved with this gas mixture using cathode analog pipeline readout. We also determine optimal parameters for the sampling algorithm in order to work in a random trigger experiment (fixed target).
Journal title
Astroparticle Physics
Record number
2000240
Link To Document