Title of article :
The leak microstructure, preliminary results
Author/Authors :
Lombardi، نويسنده , , M. and Lombardi، نويسنده , , F.S.، نويسنده ,
Pages :
5
From page :
23
To page :
27
Abstract :
The Leak Microstructure, a new type of element for position-sensitive proportional gas counter, is introduced. For every single detected ionizing radiation it gives a pair of “induced” charges of the same quantity (pulses of the same amplitude), of opposite sign, with the same collection time and essentially in time coincidence, that are proportional to the collected primary ionization. A gas multiplication up to 1.5 × 105 was achieved. The complete absence of insulating materials in the active volume of this microstructure enables to avoid problems of charging-up and makes its behaviour stable and repeatable. By using the charge-pair generated, it allows the development of a position-sensitive detecting board with a two-dimensional read-out. Between the two external surfaces of this board it is possible to insert an intermediate third conducting layer which reduces (or practically suppresses) the capacitive cross-talk between the X and Y read-out strip systems. Furthermore, this intermediate layer can give a very fast trigger to coordinate the charge-pair and to govern the data acquisition system. By reading every strip separately it is possible to resolve the multi hit problem in two-dimensions. Using isobutane as the gas, an energy resolution of about 8% FWHM was recorded with α-particles from an 241Am source. In isobutane gas, X-rays from a 55Fe source and β-particles from a 14C source were also detected.
Journal title :
Astroparticle Physics
Record number :
2001541
Link To Document :