Title of article :
Emittance measurements of the CLIO electron beam
Author/Authors :
Chaput، نويسنده , , C and Devanz، نويسنده , , G and Joly، نويسنده , , David H. Kergosien، نويسنده , , B and Lesrel، نويسنده , , J، نويسنده ,
Pages :
5
From page :
474
To page :
478
Abstract :
We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the “3 gradients” method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. e studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.
Journal title :
Astroparticle Physics
Record number :
2001853
Link To Document :
بازگشت