Title of article
Tests of a multianode PMT for the HERA-B RICH
Author/Authors
Kri?an، نويسنده , , P and Korpar، نويسنده , , S and Pestotnik، نويسنده , , Joze Staric، نويسنده , , M and Stanovnik، نويسنده , , A and Michel، نويسنده , , E. and Oehser، نويسنده , , P. and Schmidt-Parzefall، نويسنده , , W and Schwarz، نويسنده , , A and Hamacher، نويسنده , , T and Broemmelsiek، نويسنده , , D and Pyrlik، نويسنده , , J، نويسنده ,
Pages
8
From page
27
To page
34
Abstract
A new multianode photomultiplier tube, type H6568 manufactured by Hamamatsu company, has been tested in view of using it for measuring Cherenkov rings in the HERA-B experiment. The results of measurements of single-photoelectron pulse-height distributions, uniformity of response, cross-talk, photon detection efficiency, rate dependence of the gain and ageing will be presented and discussed. In addition, the response of the PMT to scintillations of perfluorobutane (C4F10), argon and air has been measured.
Journal title
Astroparticle Physics
Record number
2001890
Link To Document