• Title of article

    Observation of light from resistive plate chambers

  • Author/Authors

    Inoue، نويسنده , , Y and Kitayama، نويسنده , , I and Miyoshi، نويسنده , , Kenji Muranishi، نويسنده , , Y and Nakano، نويسنده , , E and Takahashi، نويسنده , , T and Teramoto، نويسنده , , Y، نويسنده ,

  • Pages
    9
  • From page
    65
  • To page
    73
  • Abstract
    Electrically induced signals and light emissions from Restrictive Plate Chamber (RPC) are simultaneously measured using a glass RPC with transparent high-voltage planes, operating in the streamer mode. With one exception, good correspondence is seen in between the electrical and optical signals in every aspect: signal shapes, pulse heights, timing and afterpulses. The one exception is a possible limiting effect observed on the optical signal pulse height for a given pulse height of electrically induced signal. Shapes of the signal visually observed by eye are also described.
  • Keywords
    Glass RPC , Transparent conductive paint , Resistive plate chamber (RPC)
  • Journal title
    Astroparticle Physics
  • Record number

    2001921