• Title of article

    Substrate-less, spark-free micro-strip gas counters

  • Author/Authors

    Bellazzini، نويسنده , , R. and Brez، نويسنده , , Valter A. and Latronico، نويسنده , , L. and Lumb، نويسنده , , N. and Massai، نويسنده , , M.M. and Raffo، نويسنده , , R. and Spandre، نويسنده , , G. and Spezziga، نويسنده , , M.، نويسنده ,

  • Pages
    6
  • From page
    14
  • To page
    19
  • Abstract
    We review recent work involving micro-strip gas counters with “advanced passivated” cathode strips. We present results from tests of a new variation of the MSGC, the planar micro-gap counter (PMGC), with very small (∼10 μm) anode–cathode gap. Gains of up to 3×104 were achieved and gain variations due to charging effects were less than 10% using an ordinary (uncoated) boro-silicate glass substrate. The PMGC showed no reduction in gain when subjected to an X-ray flux of 4×105 Hz/mm2 and survived exposure to alpha particles equivalent to 75 days’ running at LHC with no signs of strip damage.
  • Journal title
    Astroparticle Physics
  • Record number

    2004693