Title of article :
HSPICE simulations of Si microstrip detectors
Author/Authors :
Bacchetta، نويسنده , , N and Bisello، نويسنده , , D and Candelori، نويسنده , , A and Da Rold، نويسنده , , M and Nardi، نويسنده , , F and Paccagnella، نويسنده , , A، نويسنده ,
Pages :
5
From page :
142
To page :
146
Abstract :
We report HSPICE simulation results of the signal propagation due to a minimum ionizing particle along the strips of single-sided microstrip detectors connected to the PreShape 32 read-out electronics. The capacitive detector parameter values have been determined as a function of the width/pitch ratio by using measured and calculated data which are available in literature. The strip load capacitance, i.e. the capacitance at the read-out electronics input due to the detector has been calculated by using HSPICE simulations. Different read-out configurations have been investigated.
Journal title :
Astroparticle Physics
Record number :
2004908
Link To Document :
بازگشت