Author/Authors :
Verdan، نويسنده , , Simon and Burato، نويسنده , , Guillaume and Comet، نويسنده , , Marc and Reinert، نويسنده , , Laurence and Fuzellier، نويسنده , , Hervé، نويسنده ,
Abstract :
The effect of ultrasounds on the surface of metallic plates with cubic faced centered (Al, Ag, Cu) or hexagonal (Zn) structure was studied. Treated surfaces were strongly attacked: a micrometric roughness and a superficial oxidation (characterized by roughness measurements and scanning electron microscopy) were induced. X-ray diffraction analyses showed a preferential reorientation of the maximum density planes for both crystallographic structures.
Keywords :
Ultrasonic attack , Metals , Crystal reorientation , Roughness