Title of article :
The gain control system for the COPP (coincidence photon–proton) apparatus
Author/Authors :
Capitani، نويسنده , , G.P. and Luxardo، نويسنده , , S. and Massone، نويسنده , , A.M. and Ottonello، نويسنده , , P. and Reolon، نويسنده , , A.R. and Sanzone، نويسنده , , M. and Zucchiatti، نويسنده , , A.، نويسنده ,
Pages :
9
From page :
166
To page :
174
Abstract :
We have built and operated a system which monitors and controls the response of the 12 lead-glass and the 12 plastic scintillator detectors in the COincidence Photon–Proton (COPP) apparatus. We present here the detailed operation of the system and its performances during the experiment’s runs. The gain control system, acting on the high-voltage values of the photomultiplier tubes, allows one to achieve a long term gain stability as good as 2% for each detector.
Keywords :
Gain control system , PMT gain , Detector response stability
Journal title :
Astroparticle Physics
Record number :
2005912
Link To Document :
بازگشت