• Title of article

    New flowmetric measurement methods of power dissipated by an ultrasonic generator in an aqueous medium

  • Author/Authors

    Mancier، نويسنده , , Valérie and Leclercq، نويسنده , , Didier، نويسنده ,

  • Pages
    8
  • From page
    99
  • To page
    106
  • Abstract
    Two new determination methods of the power dissipated in an aqueous medium by an ultrasound generator were developed. They are based on the use of a heat flow sensor inserted between a tank and a heat sink that allows to measure the power directly coming through the sensor. To be exploitable, the first method requires waiting for stationary flow. On the other hand, the second, extrapolated from the first one, makes it possible to determine the dissipated power in only five minutes. Finally, the results obtained with the flowmetric method are compared to the classical calorimetric ones.
  • Keywords
    Ultrasounds , Thermodynamics , Calorimeter , power measurement , Thermal flowmeter
  • Journal title
    Astroparticle Physics
  • Record number

    2006057