Title of article :
Radiation hardness evaluation of the Analog Devices AD9042 ADC for use in the CMS electromagnetic calorimeter
Author/Authors :
Denes، نويسنده , , P. and Lev، نويسنده , , B. and Wixted، نويسنده , , R.، نويسنده ,
Abstract :
We report on the results of an irradiation study carried out on devices from all wafers in a lot of AD9042 40 MHz 12-bit ADCs. These devices were irradiated in a 72 MeV proton beam in order to simulate the effects in CMS at the LHC. No change in dynamic performance was observed for doses up to 2×104 Gy along with 4×1013 n/cm2. The uniform behavior of all devices in the lot also indicates that radiation hardness can be assured by sampling tests on devices from one wafer in the lot.
Keywords :
ADC , Radiation hardness , CMS
Journal title :
Astroparticle Physics