Carman، نويسنده , , D.S. and Dytman، نويسنده , , S.A. and Magahiz، نويسنده , , R. and Mestayer، نويسنده , , M.D. and Miskimen، نويسنده , , R.A. and Mueller، نويسنده , , J.A. and Schumacher، نويسنده , , R.A. and Tedeschi، نويسنده , , D.J. and Thompson، نويسنده , , R.A. and Wilkin، نويسنده , , G.R.، نويسنده ,
Pages :
5
From page :
315
To page :
319
Abstract :
The Region One detector is the innermost of three nested drift chamber packages of the CLAS spectrometer at Jefferson Laboratory. This detector, with 7776 drift cells, was optimized for the CLAS toroidal magnet geometry, and consists of six wedge-shaped sectors integrated into a single unit. Each sector has thin and relatively weak aluminum endplates which support the large mechanical loads from the wire tensions and associated readout hardware. The unusual feature of the detector is its self-supporting design, wherein the wire tensions of neighboring sectors balance each other without the use of massive structural support. We discuss the design criteria, mechanical components, and assembly procedures.