Author/Authors :
Mart?? i Garcia، نويسنده , , S. and Allport، نويسنده , , P.P. and Booth، نويسنده , , P.S.L. and Greenall، نويسنده , , A. and Jackson، نويسنده , , J.N and Jones، نويسنده , , T.J. and Smith، نويسنده , , N.A.، نويسنده ,
Abstract :
The charge collection efficiency of the n+n silicon microstrip detectors for the ATLAS forward tracking has been evaluated for detectors irradiated with 24 GeV/c protons. The charge collection efficiency is found to be 99±1% after a fluence of 2×1014 protons/cm2 and 81±2% after 4×1014 protons/cm2. Furthermore, the charge collection efficiency of the detector irradiated with the lower dose does not show any dependence on the isothermal annealing up to 52 days at 20°C, as it remains constant through the whole annealing cycle.