Title of article :
Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
Author/Authors :
Raczy?ski، نويسنده , , L. and Moskal، نويسنده , , P. and Kowalski، نويسنده , , P. and Wi?licki، نويسنده , , W. and Bednarski، نويسنده , , T. and Bia?as، نويسنده , , Krzysztof P. and Czerwinski، نويسنده , , E. and Kap?on، نويسنده , , ?. and Kochanowski، نويسنده , , A. and Korcyl، نويسنده , , G. and Kowal، نويسنده , , J. and Kozik، نويسنده , , T. and Krzemie?، نويسنده , , W. and Kubicz، نويسنده , , E. and Molenda، نويسنده , , M. and Moskal، نويسنده , , I. and Nied?wiecki، نويسنده , , Sz. and Pa?ka، نويسنده , , M. and Pawlik-Nied?wiecka، نويسنده , , Chi M. and Rudy Wu، نويسنده , , Z. and Salabura، نويسنده , , P. and Sharma، نويسنده , , N.G. and Silarski، نويسنده , , M. and S?omski، نويسنده , , A. and Smyrski، نويسنده , , J. and Strzelecki، نويسنده , , A. and Wieczorek، نويسنده , , A. and Zieli?ski، نويسنده , , M. and Zo?، نويسنده , , N.، نويسنده ,
Pages :
7
From page :
186
To page :
192
Abstract :
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511 keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps (σ).
Keywords :
Plastic scintillators , Statistical analysis , Positron emission tomography
Journal title :
Astroparticle Physics
Record number :
2009113
Link To Document :
بازگشت