Title of article :
Development of GAGG depth-of-interaction (DOI) block detectors based on pulse shape analysis
Author/Authors :
Yamamoto، نويسنده , , Seiichi and Kobayashi، نويسنده , , Takahiro and Yeol Yeom، نويسنده , , Jung and Morishita، نويسنده , , Yuki and Sato، نويسنده , , Hiroki and Endo، نويسنده , , Takanori and Usuki، نويسنده , , Yoshiyuki and Kamada، نويسنده , , Kei and Yoshikawa، نويسنده , , Akira، نويسنده ,
Pages :
7
From page :
289
To page :
295
Abstract :
A depth-of-interaction (DOI) detector is required for developing a high resolution and high sensitivity PET system. Ce-doped Gd3Al2Ga3O12 (GAGG fast: GAGG-F) is a promising scintillator for PET applications with high light output, no natural radioisotope and suitable light emission wavelength for semiconductor based photodetectors. However, no DOI detector based on pulse shape analysis with GAGG-F has been developed to date, due to the lack of appropriate scintillators of pairing. Recently a new variation of this scintillator with different Al/Ga ratios—Ce-doped Gd3Al2.6Ga2.4O12 (GAGG slow: GAGG-S), which has slower decay time was developed. The combination of GAGG-F and GAGG-S may allow us to realize high resolution DOI detectors based on pulse shape analysis. We developed and tested two GAGG phoswich DOI block detectors comprised of pixelated GAGG-F and GAGG-S scintillation crystals. One phoswich block detector comprised of 2×2×5 mm pixel that were assembled into a 5×5 matrix. The DOI block was optically coupled to a silicon photomultiplier (Si-PM) array (Hamamatsu MPPC S11064-050P) with a 2-mm thick light guide. The other phoswich block detector comprised of 0.5×0.5×5 mm (GAGG-F) and 0.5×0.5×6 mm3 (GAGG-S) pixels that were assembled into a 20×20 matrix. The DOI block was also optically coupled to the same Si-PM array with a 2-mm thick light guide. In the block detector of 2-mm crystal pixels (5×5 matrix), the 2-dimensional histogram revealed excellent separation with an average energy resolution of 14.1% for 662-keV gamma photons. The pulse shape spectrum displayed good separation with a peak-to-valley ratio of 8.7. In the block detector that used 0.5-mm crystal pixels (20×20 matrix), the 2-dimensional histogram also showed good separation with energy resolution of 27.5% for the 662-keV gamma photons. The pulse shape spectrum displayed good separation with a peak-to-valley ratio of 6.5. These results indicate that phoswich DOI detectors with the two types of GAGGs are promising for developing a high resolution PET system.
Keywords :
Decay time , Pulse shape , DOI detector , GAGG
Journal title :
Astroparticle Physics
Record number :
2009455
Link To Document :
بازگشت