• Title of article

    Powder-phosphor screens combined with interference filters for X-ray imaging with increased brightness

  • Author/Authors

    Koch، نويسنده , , Andreas and Rosenfeldt، نويسنده , , Harald، نويسنده ,

  • Pages
    6
  • From page
    358
  • To page
    363
  • Abstract
    Powder-phosphor screens are frequently used in X-ray imaging devices. They have an angular light emission characteristic which is close to a cosine distribution (Lambertian) of photometric intensity. If interference filters are combined with these screens, the angular-emission characteristic changes. We have developed interference filters for powder-phosphor screens with increased brightness perpendicular to the screen. This is particularly advantageous for screens viewed by lens-optic or fiber-optic systems. Measurements on powder-phosphor screens (Gd2O2S:Tb screens, thickness 50 μm) with interference filters were carried out at X-ray photon energies of 18 keV. For an optical system with a numerical aperture of 0.25, the transmitted signal power increased by 70%. However, the spatial resolution was worse compared to the same screen without a filter; 31 μm fwhm was measured without a filter and 43 μm fwhm with a filter.
  • Keywords
    Optical filter , Interference filter , X-ray detector , luminescent screen , Phosphor screen , x-ray imaging
  • Journal title
    Astroparticle Physics
  • Record number

    2009694