• Title of article

    Measurement of the thermal and fast neutron flux in a research reactor with a Li and Th loaded optical fibre detector

  • Author/Authors

    Yamane، نويسنده , , Y and Uritani، نويسنده , , A and Misawa، نويسنده , , T and Karlsson، نويسنده , , J.K.-H and Pلzsit، نويسنده , , I، نويسنده ,

  • Pages
    7
  • From page
    403
  • To page
    409
  • Abstract
    The spatial dependence of thermal and fast neutron flux was measured axially in the core of a 1 MW research reactor. The measurements were made by a thin optical fibre detector with a neutron sensitive ZnS(Ag) scintillation tip. For thermal neutrons 6Li was used, whereas for fast neutrons 232Th was used as neutron converter. The spatial dependence was measured by moving the fibre axially with a uniform speed. The measurement takes a few minutes, compared to up to 10 h with the conventional wire activation method. Comparison with traditional measurements shows a good agreement.
  • Keywords
    Optical fibre , research reactor , Axial flux measurement , scintillation detector
  • Journal title
    Astroparticle Physics
  • Record number

    2009704