• Title of article

    Double sided irradiation on homogenous products of different densities at an industrial EB accelerator of 2 MeV energy

  • Author/Authors

    Benny، نويسنده , , P.G. and Khader، نويسنده , , S.A. and Sarma، نويسنده , , K.S.S.، نويسنده ,

  • Pages
    4
  • From page
    25
  • To page
    28
  • Abstract
    An industrial type 2 MeV/20 kW electron beam accelerator is operational in India for development of applications and technology demonstration to the Indian industry in the field of polymer modifications and for processing of various other products. For routine monitoring of beam current during radiation processing of products at the facility, a current density measurement system was fabricated using high quality graphite material. Depth–dose distribution was experimentally measured in materials of different densities for optimizing suitable thickness for double sided irradiation under 2 MeV beam. The present paper describes the features of the current density measurement system and experiments for optimizing thickness suitable for double sided irradiation for materials of different densities.
  • Keywords
    dosimetry , Dose optimization , Electron beam accelerator , Double-sided irradiation , Depth–dose distribution
  • Journal title
    Astroparticle Physics
  • Record number

    2009879