Title of article
The role of space charge in GaAs-based particle detectors
Author/Authors
Mare?، نويسنده , , J.J and Kri?tofik، نويسنده , , J and Hub??k، نويسنده , , P and Posp???il، نويسنده , , S، نويسنده ,
Pages
4
From page
57
To page
60
Abstract
The direct measurement of the captured charge using the Faraday cup method together with the analysis of current–voltage curves was used for the experimental proof of the existence of the space charge in biased GaAs detector structures. The role of this space charge was discussed using the generalized Ramo–Gunnʹs theorem which enabled the explanation of the data observed and, moreover, provides a useful criterion for the optimization of GaAs-based particle detectors.
Keywords
Gallium arsenide , Radiation detectors , Space charge , Faraday cup method
Journal title
Astroparticle Physics
Record number
2009951
Link To Document