Adams، نويسنده , , D and Adeva، نويسنده , , B and Arik، نويسنده , , E and Arvidson، نويسنده , , A and Badelek، نويسنده , , B and Ballintijn، نويسنده , , M.K. and Bardin، نويسنده , , G and Baum، نويسنده , , G and Berglund، نويسنده , , P and Betev، نويسنده , , L and Bird، نويسنده , , I.G. and Birsa، نويسنده , , R and Bjِrkholm، نويسنده , , P and Bonner، نويسنده , , B.E and de Botton، نويسنده , , N and Boutemeur، نويسنده , , M and Bradamante، نويسنده , , F and، نويسنده ,
Pages :
21
From page :
354
To page :
374
Abstract :
Arrays of limited streamer tubes of the Iarocci type were deployed in our experiment at CERN as part of a forward muon detector system with provisions for the beam to pass through the center of each panel in the array. A total of 16 4 m×4 m panels were assembled with inductive readout strips on both sides of each panel. An active feedback system was deployed to regulate the high voltage to the streamer tubes to insure a constant efficiency for minimum ionizing particles. The arrays were operated in this environment for over five years of data taking. Streamer tube track-reconstruction efficiencies and tube replacement rates are reported.