• Title of article

    Optimization of the scan protocols for CT-based material extraction in small animal PET/CT studies

  • Author/Authors

    Yang، نويسنده , , Ching-Ching and Yu، نويسنده , , Jhih-An and Yang، نويسنده , , Bang-Hung and Wu، نويسنده , , Tung-Hsin، نويسنده ,

  • Pages
    6
  • From page
    299
  • To page
    304
  • Abstract
    We investigated the effects of scan protocols on CT-based material extraction to minimize radiation dose while maintaining sufficient image information in small animal studies. The phantom simulation experiments were performed with the high dose (HD), medium dose (MD) and low dose (LD) protocols at 50, 70 and 80 kVp with varying mA s. The reconstructed CT images were segmented based on Hounsfield unit (HU)-physical density (ρ) calibration curves and the dual-energy CT-based (DECT) method. Compared to the (HU;ρ) method performed on CT images acquired with the 80 kVp HD protocol, a 2-fold improvement in segmentation accuracy and a 7.5-fold reduction in radiation dose were observed when the DECT method was performed on CT images acquired with the 50/80 kVp LD protocol, showing the possibility to reduce radiation dose while achieving high segmentation accuracy.
  • Keywords
    Dual-energy computed tomography , Material extraction , radiation dose
  • Journal title
    Astroparticle Physics
  • Record number

    2010231