Title of article :
Optimal temporal windows and dose-reducing strategy for coronary artery bypass graft imaging with 256-slice CT
Author/Authors :
Lu، نويسنده , , Kun-Mu and Lee، نويسنده , , Yi-Wei and Guan، نويسنده , , Yuxiang and Chen، نويسنده , , Liang-Kuang and Law، نويسنده , , Wei-Yip and Su، نويسنده , , Chen-Tau and Hsu MD، نويسنده ,
Pages :
6
From page :
309
To page :
314
Abstract :
AbstractObjective ermine the optimal image reconstruction windows in the assessment of coronary artery bypass grafts (CABGs) with 256-slice computed tomography (CT), and to assess their associated optimal pulsing windows for electrocardiogram-triggered tube current modulation (ETCM). s ruited 18 patients (three female; mean age 68.9 years) having mean heart rate (HR) of 66.3 beats per minute (bpm) and a heart rate variability of 1.3 bpm for this study. A total of 36 CABGs with 168 segments were evaluated, including 12 internal mammary artery (33.3%) and 24 saphenous vein grafts (66.7%). We reconstructed 20 data sets in 5%-step through 0–95% of the R–R interval. The image quality of CABGs was assessed by a 5-point scale (1=excellent to 5=non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Two reviewers discriminated optimal reconstruction intervals for each CABG segment in each temporal window. Optimal windows for ETCM were also evaluated. s termined optimal systolic and diastolic reconstruction intervals could be divided into 2 groups with threshold HR=68. The determined best reconstruction intervals for low heart rate (HR<68) and high heart rate (HR>68) were 76.0±2.5% and 45.0±0% respectively. Average image quality scores were 1.7±0.6 with good inter-observer agreement (Kappa=0.79). Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001). The recommended windows of ETCM for low HR, high HR and all HR groups were 40–50%, 71–81% and 40–96% of R-R interval, respectively. The corresponding dose savings were about 60.8%, 58.7% and 22.7% in that order. sions ermined optimal reconstruction intervals and ETCM windows representing a good compromise between radiation and image quality for following bypass surgery using a 256-slice CT.
Keywords :
Computed tomography angiogram , coronary artery bypass graft , image quality , Electrocardiogram-based tube current modulation , radiation dose
Journal title :
Astroparticle Physics
Record number :
2010235
Link To Document :
بازگشت