Title of article :
RoSiB – a 4π silicon ball for charged-particle detection in EUROBALL
Author/Authors :
Pausch، نويسنده , , G. and Prade، نويسنده , , H. and Sobiella، نويسنده , , M. and Schnare، نويسنده , , H. and Schwengner، نويسنده , , R. and K?ubler، نويسنده , , L. and Borcan، نويسنده , , C. and Ortlepp، نويسنده , , H.-G. and Oehmichen، نويسنده , , U. and Grawe، نويسنده , , H. and Schubart، نويسنده , , R. and Gerl، نويسنده , , J. and Cederk?ll، نويسنده , , J. and Johnson، نويسنده , , A. and Kerek، نويسنده , , A. and Klamra، نويسنده , , W. and Moszy?ski، نويسنده , , M. and Wolski، نويسنده , , D. and Kapusta، نويسنده , , M. and Axelsson، نويسنده , , A. and Weiszflog، نويسنده , , M. and H?rtlein، نويسنده , , T. and Pansegrau، نويسنده , , D. F. De Angelis، نويسنده , , G. Hossein Ashrafi، نويسنده , , S. and Likar، نويسنده , , A. and Lipoglav?ek، نويسنده , , M.، نويسنده ,
Pages :
15
From page :
304
To page :
318
Abstract :
A 4π silicon ball for detection and identification of light charged particles in large multidetector γ-arrays as EUROBALL is presented. The design is based on a N=42 ball with 12 pentagons and 30 hexagons as used in the GASP array. The absorptive material for γ-rays is minimized to the detector thickness of 300 or 500 μm and a 0.63 mm ceramic backing. The geometrical coverage is designed for about 90% of 4π. A pulse shape discrimination method with totally depleted detectors working in the reverse mount allows identifying protons and α-particles above an energy threshold of about 2 MeV. The performances of the ball were tested at the tandem – booster accelerator combination of the MPI Heidelberg in two experiments using the high-recoil reaction of 228 MeV 58Ni+46Ti and the low-recoil reaction of 95 MeV 16O+58Ni. The two-dimensional spectra of zero-crossing (ZC) versus energy confirmed an excellent discrimination of protons and α-particles in all the detectors at different angles. The energy spectra of protons and α-particles measured in the experiments are presented, too. The γ-spectra measured in coincidence with various combinations of emitted particles showed a high selectivity of the ball. The reduced total efficiency for protons of 59% and 55% and α-particles of 44% and 32% measured in a nuclear spectroscopy application is analyzed in a Monte-Carlo simulation (GEANT). It is due to a combined influence of a thick target needed to stop the recoiling residual nuclei and thick absorbers needed to protect the Si-detectors from scattered beam. The results along with the GEANT extrapolation to optimum experimental conditions confirm that RoSiB is a highly efficient and selective device for identification of rare reaction channels with heavy ions.
Keywords :
detection , Charged particle , EUROBALL Si-ball , Pulse shape discrimination with Si-detectors
Journal title :
Astroparticle Physics
Record number :
2011619
Link To Document :
بازگشت