Author/Authors :
Garg، نويسنده , , Akash Deep and Karnewar، نويسنده , , A.K. and Ojha، نويسنده , , A. K. Shrivastava، نويسنده , , B.B. and Holikatti، نويسنده , , A.C. and Puntambekar، نويسنده , , T.A. and Navathe، نويسنده , , C.P.، نويسنده ,
Abstract :
Indus-2 is a 2.5 GeV synchrotron radiation source (SRS) operational at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We have designed, developed and commissioned x-ray diagnostic beam line (X-DBL) at the Indus-2. It is based on pinhole array imaging (8–18 keV). We have derived new equations for online measurements of source position and emission angle with pinhole array optics. Measured values are compared with the measurements at an independent x-ray beam position monitor (staggered pair blade monitor) installed in the X-DBL. The measured values are close to the theoretical expected values within ±12 µm (or ±1.5 μrad) for sufficiently wide range of the beam movements. So, beside the beam size and the beam emittance, online information for the vertical position and angle is also used in the orbit steering. In this paper, the various design considerations of the X-DBL and online measurement results are presented.
Keywords :
Staggered pair blade monitor , Synchrotron radiation , Diagnostics beam line , Pinhole array , X-ray beam position monitor