Title of article :
High-resolution tracking using large capillary bundles filled with liquid scintillator
Author/Authors :
Annis، نويسنده , , P and Bay، نويسنده , , A and Benussi، نويسنده , , R. and Bruski، نويسنده , , N and Buontempo، نويسنده , , S and Currat، نويسنده , , C and DʹAmbrosio، نويسنده , , N and van Dantzig، نويسنده , , R and Dupraz، نويسنده , , J and Ereditato، نويسنده , , A and Fabre، نويسنده , , J.P and Fanti، نويسنده , , V and Feyt، نويسنده , , J and Frekers، نويسنده , , D and Frenkel، نويسنده , , A and Galeazzi، نويسنده , , F and Garufi، نويسنده , , F and Goldberg، نويسنده , , J and Golovkin، نويسنده , , S.V and Gorin، نويسنده , , A.M and Grégoire، نويسنده , , G and Harrison، نويسنده , , K and Hoepfner، نويسنده , , K and Holtz، نويسنده , , K and Konijn، نويسنده , , J and Kozarenko، نويسنده , , E.N. and Kreslo، نويسنده , , I.E. and Kushnirenko، نويسنده , , A.E and Liberti، نويسنده , , B and Martellotti، نويسنده , , G and Medvedkov، نويسنده , , A.M and Michel، نويسنده , , L and Migliozzi، نويسنده , , P and Mommaert، نويسنده , , C and Mondardini، نويسنده , , M.R. and Panman، نويسنده , , J and Penso، نويسنده , , G and Petukhov، نويسنده , , Y.P and Rondeshagen، نويسنده , , D and Siegmund، نويسنده , , W.P and Tyukov، نويسنده , , V and Beek، نويسنده , , G.Van and Vasilʹchenko، نويسنده , , V.G and Vilain، نويسنده , , P and Visschers، نويسنده , , J.L. and Wilquet، نويسنده , , G and Winter، نويسنده , , K and Wolff، نويسنده , , T and Wِrtche، نويسنده , , H.J and Wong، نويسنده , , V.G and Zimyn، نويسنده , , K.V، نويسنده ,
Pages :
21
From page :
60
To page :
80
Abstract :
We have developed large high-resolution tracking detectors based on glass capillaries filled with organic liquid scintillator of high refractive index. These liquid-core scintillating optical fibres act simultaneously as detectors of charged particles and as image guides. Track images projected onto the readout end of a capillary bundle are visualized by an optoelectronic chain consisting of a set of image-intensifier tubes followed by a photosensitive CCD or by an EBCCD camera. Two prototype detectors, each composed of ≈106 capillaries with 20–25 μm diameter and 0.9–1.8 m length, have been tested, and a spatial resolution of the order of 20–40 μm has been attained. A high scintillation efficiency and a large light-attenuation length, in excess of 3 m, was achieved through special purification of the liquid scintillator. Along the tracks of minimum-ionizing particles, the hit densities obtained were ∼8 hits/mm at the readout window, and ∼3 hits/mm at ∼1 m away. The level of radiation resistance of the prototype detectors is at least an order of magnitude higher than that of other tracking devices of comparable performance.
Keywords :
Tracking and position-sensitive detectors , Scintillating fibres , Scintillation detectors , Optoelectronics , image intensifiers , CCD
Journal title :
Astroparticle Physics
Record number :
2012473
Link To Document :
بازگشت