Title of article :
Monitoring system for a synthesizer at SPring-8 synchrotron radiation facility and obtained results
Author/Authors :
Kawashima، نويسنده , , Y. and Ego، نويسنده , , H. and Hara، نويسنده , , M. and Ohashi، نويسنده , , Y. and Ohshima، نويسنده , , T. and Takao، نويسنده , , M. and Takashima، نويسنده , , T.، نويسنده ,
Pages :
6
From page :
243
To page :
248
Abstract :
Beam orbit distortion in all dispersive sections was observed in the SPring-8 storage ring during beam commissioning. In order to confirm the stability of the radio frequency (RF) synthesizer, a monitoring system was developed. The system consists of a frequency counter referenced to a global positioning system (GPS) receiver. With this system, the output of the synthesizer, which uses an external 10 MHz-Rubidium atomic clock with the time accuracy of Δ t / t = 10 − 12 , is correctly monitored with 11 digits absolute accuracy, verifying that the synthesizer works well. Measurement of the circumference of the SPring-8 storage ring reveals the effect of tidal forces and seasonal temperature variations on beam orbit. To maintain the center axis of photon radiation in experimental beam lines, a beam energy correction is carried out. The frequency of the RF synthesizer is changed every 5 min with 10-digit accuracy. This corresponds to an energy accuracy of Δ E / E = 1.16 × 10 − 6 . The monitoring system for the synthesizer and obtained results are described.
Keywords :
Radio frequency , Synthesizer , Tidal forces , Energy correction , Atomic clock , SPring-8
Journal title :
Astroparticle Physics
Record number :
2012570
Link To Document :