Title of article :
Beam injection system on a movable plate for the Taiwan Photon Source
Author/Authors :
Chan، نويسنده , , C.K. and Chang، نويسنده , , C.C. and Chen، نويسنده , , C.L. and Yang، نويسنده , , C.S. and Hsu، نويسنده , , K.H. and Huang، نويسنده , , Y.T. and Kuan، نويسنده , , C.K. and Hsueh، نويسنده , , H.P. and Hsu، نويسنده , , S.N. and Chou، نويسنده , , P.J. and Hsiung، نويسنده , , G.Y. and Chen، نويسنده , , J.R.، نويسنده ,
Pages :
7
From page :
56
To page :
62
Abstract :
The Taiwan Photon Source (TPS) is a 3-GeV synchrotron facility designed to have a low-emittance electron beam and to be maintained with top-up operation. A TPS injection section (length 12 m) contains four injection kickers (K1–K4) and one injection septum outside vacuum to provide the stored beam with a horizontal bump for beam injection off axis. Kickers K2 and K3 and the injection septum are placed in an adjustable plate, which can provide displacement of 5 mm for the injected beam near the stored beam so as to decrease the kicker strength. The construction of the injection section is completed; we here describe its design and manufacture, and present some test results for the injection section.
Keywords :
Septum , Synchrotron , Kicker , Injection section
Journal title :
Astroparticle Physics
Record number :
2012892
Link To Document :