Title of article :
QCALT: A tile calorimeter for KLOE-2 upgrade
Author/Authors :
Balla، نويسنده , , A. and Ciambrone، نويسنده , , P. and Corradi، نويسنده , , G. and Martini، نويسنده , , M. and Paglia، نويسنده , , Heloيsa C. and Pileggi، نويسنده , , G. and Ponzio، نويسنده , , B. and Saputi، نويسنده , , A. and Tagnani، نويسنده , , D.، نويسنده ,
Pages :
2
From page :
95
To page :
96
Abstract :
The upgrade of the Da Φ ne machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE-2, thus asking for the realization of two new calorimeters, named QCALT, covering this area. To improve the reconstruction of K L → 2 π 0 events with photons hitting the quadrupoles, a calorimeter with high efficiency to low energy photons (20–300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. To match these requirements we are now constructing a scintillator tile calorimeter where each single tile is readout by mean of SiPM for a total granularity of 1760 channels. We show the design of the different calorimeter components and the present status of the construction.
Keywords :
SiPM , Tiles , KLOE-2 , Sampling calorimeters
Journal title :
Astroparticle Physics
Record number :
2013198
Link To Document :
بازگشت