Title of article
Indoor radon detected by compact discs
Author/Authors
Pressyanov، نويسنده , , D. and Buysse، نويسنده , , J. and Van Deynse، نويسنده , , A. and Poffijn، نويسنده , , A. and Meesen، نويسنده , , G.، نويسنده ,
Pages
2
From page
665
To page
666
Abstract
An approach for a precise retrospective assessment of the indoor radon exposure using commercial compact discs (CDs) is proposed. It is based on the remarkable radon absorption and α track-etch properties of polycarbonate — the basic material of the CDs. The experimental results indicate that the useful range of this approach is able to cover practically the entire range of indoor 222Rn concentrations.
Keywords
RADON , Retrospective measurements , Compact disks
Journal title
Astroparticle Physics
Record number
2013933