• Title of article

    Highly sensitive radon monitor and radon emanation rates for detector components

  • Author/Authors

    Choi، نويسنده , , E. and Komori، نويسنده , , M. and Takahisa، نويسنده , , K. and Kudomi، نويسنده , , N. and Kume، نويسنده , , K. and Hayashi، نويسنده , , K. and Yoshida، نويسنده , , S. and Ohsumi، نويسنده , , H. and Ejiri، نويسنده , , H. and Kishimoto، نويسنده , , T. and Matsuoka، نويسنده , , K. and Tasaka، نويسنده , , S.، نويسنده ,

  • Pages
    5
  • From page
    177
  • To page
    181
  • Abstract
    The radon emanation rates for materials were measured by using the electrostatic precipitation method as a radon monitor. It was found that a low level of radon was emanated from several material components in ELEGANT V. The radon monitor has been developed for the highly sensitive measurements of low-level radon concentration. The system was shown to have a sensitivity to radon concentrations as low as 1.6 mBq/m3 for one day measurement. The system was also used as the radon concentration monitor for the gas inside the airtight box of the ELEGANT V at Oto Cosmo Observatory.
  • Keywords
    Radon concentration , High sensitive radon monitor , Detector component
  • Journal title
    Astroparticle Physics
  • Record number

    2013972