• Title of article

    Spatial resolution and rate capability of MICROMEGAS detector

  • Author/Authors

    Derré، نويسنده , , J. and Giomataris، نويسنده , , I.، نويسنده ,

  • Pages
    3
  • From page
    74
  • To page
    76
  • Abstract
    We report on recent measurements of MICROMEGAS: spatial resolution and rate capability.The spatial resolution has been studied using several gas mixtures at the CERN PS test beam. With a gas filling of CF4 and 20% isobutane, an accuracy of 12 μm has been measured at normal incidence. Optimized conditions and gas mixtures for operation at high-rate environments have been found.
  • Journal title
    Astroparticle Physics
  • Record number

    2014269