Title of article
The fast extraction kicker power supply for the main ring of J-PARC
Author/Authors
Koseki، نويسنده , , Kunio، نويسنده ,
Pages
5
From page
3
To page
7
Abstract
An effect induced by parasitic inductance in a pulsed power supply for a fast extraction kicker was studied. The parasitic inductance in high voltage capacitors for a low impedance pulse forming network disturbs a sharp rise of an excitation current. A high voltage capacitor with a coaxial structure to minimize the parasitic inductance is proposed. The effectiveness was confirmed experimentally. An impedance mismatch by a leakage inductance of a pulse transformer in a transmission line was studied. The effect is serious at the flat-top period of the excitation current. By introducing a compensation circuit, which is composed by a capacitor and a resistor, impedance matching was established. The pulsed power supply for the fast extraction kicker was operated at a charging voltage of 30 kV. A required rise time of less than 1.1 μs was achieved. The flatness was also confirmed to be in an acceptable value of less than 1%.
Keywords
Pulse , POWER SUPPLY , magnet
Journal title
Astroparticle Physics
Record number
2014335
Link To Document