Author/Authors :
M.T. and Codino، نويسنده , , A.، نويسنده ,
Abstract :
The parameters governing the time resolution of a gallium arsenide strip telescope have been studied in various experimental conditions. The GaAs strip detectors are connected with a classical readout chain made of preamplifier, amplifier, constant-fraction discriminator and time-to-digital converter. The electronic noise, the amplitude and the fall time of the amplifier output pulse have been measured from −55°C to 20°C. The mean value of the fall time is 950 ps at −55°C and has a linear dependence on the temperature. The time resolution of the gallium arsenide telescope is 173 ps at 20°C. A silicon strip telescope processed by the same readout chain exhibits a time resolution of 213 ps.