Title of article
Characterization of EASIROC as front-end for the readout of the SiPM at the focal plane of the Cherenkov telescope ASTRI
Author/Authors
Impiombato، نويسنده , , D. and Giarrusso، نويسنده , , S. and Mineo، نويسنده , , T. and Belluso، نويسنده , , M. and Billotta، نويسنده , , S. and Bonanno، نويسنده , , G. and Catalano، نويسنده , , O. and Grillo، نويسنده , , A. and La Rosa، نويسنده , , G. C. Marano، نويسنده , , D. and Sottile، نويسنده , , G.، نويسنده ,
Pages
7
From page
484
To page
490
Abstract
The Extended Analogue Silicon Photo-multiplier Integrated Read Out Chip, EASIROC, is a chip proposed as front-end of the camera at the focal plane of the imaging Cherenkov ASTRI SST-2M telescope prototype. This paper presents the results of the measurements performed to characterize EASIROC in order to evaluate its compliance with the ASTRI SST-2M focal plane requirements. In particular, we investigated the trigger time walk and the jitter effects as a function of the pulse amplitude. The EASIROC output signal is found to vary linearly as a function of the input pulse amplitude with very low level of electronic noise and cross-talk ( < 1 % ). Our results show that it is suitable as front-end chip for the camera prototype, although, specific modifications are necessary to adopt the device in the final version of the telescope.
Journal title
Astroparticle Physics
Record number
2014474
Link To Document