Title of article
Hybrid Monte-Carlo method for simulating neutron and photon radiography
Author/Authors
Wang، نويسنده , , Han and Tang، نويسنده , , Vincent، نويسنده ,
Pages
7
From page
728
To page
734
Abstract
We present a Hybrid Monte-Carlo method (HMCM) for simulating neutron and photon radiographs. HMCM utilizes the combination of a Monte-Carlo particle simulation for calculating incident film radiation and a statistical post-processing routine to simulate film noise. Since the method relies on MCNP for transport calculations, it is easily generalized to most non-destructive evaluation (NDE) simulations. We verify the methodʹs accuracy through ASTM Internationalʹs E592-99 publication, Standard Guide to Obtainable Equivalent Penetrameter Sensitivity for Radiography of Steel Plates [1]. Potential uses for the method include characterizing alternative radiological sources and simulating NDE radiographs.
Keywords
Radiography , X-Ray , MCNP , SIMULATION , Neutron imaging , Gamma imaging