Title of article
Testbeam results for the SiW electromagnetic calorimeter
Author/Authors
Giannelli، نويسنده , , Michele Faucci، نويسنده ,
Pages
3
From page
234
To page
236
Abstract
A prototype of a highly granular SiW electromagnetic calorimeter composed of 6480 cells contained in a volume of 18×18×30 cm3 was installed and tested in 2006 at CERN by the CALICE collaboration. The analysis focuses on the resolution of the calorimeter to electromagnetic showers. The energy resolution was found to be 16.6 ± 0.1 / E ( GeV ) ⊕ 1.1 ± 0.1 ( % ) while the linearity was better than 1%. The analysis on embedded electronics showed no sign of signal induced by the shower.
Keywords
CALICE , Silicon detector , Electromagnetic calorimeter , Embedded electronics , iLC , Electron reconstruction
Journal title
Astroparticle Physics
Record number
2014985