    Fast high resolution gaseous detectors for diffraction experiments and imaging at synchrotron radiation beam

  • Author/Authors

    Aulchenko، نويسنده , , V.M. and Baru، نويسنده , , S.E. and Evdokov، نويسنده , , O.V. and Leonov، نويسنده , , V.V. and Papushev، نويسنده , , P.A. and Porosev، نويسنده , , V.V. and Savinov، نويسنده , , G.A. and Sharafutdinov، نويسنده , , M.R. and Shekhtman، نويسنده , , L.I. and Ten، نويسنده , , K.A. and Titov، نويسنده , , V.M. and Tolochko، نويسنده , , B.P. and Vasiljev، نويسنده , , A.V. and Zhogin، نويسنده , , I.L. and Z، نويسنده ,

  • Pages
    3
  • From page
    600
  • To page
    602
  • Abstract
    The series of high-rate and high spatial resolution gaseous detectors for diffraction studies and X-ray imaging at SR beam developed in the Budker INP is reviewed. The detectors are based on wire and micro-pattern gas technologies and provide spatial resolution at the level of 0.1 mm together with rate capability in the range from 10 MHz per detector to ∼ 10 10 Hz / channel .
  • Keywords
    GEM , Gaseous detectors , Position-sensitive detectors
  • Journal title
    Astroparticle Physics
  • Record number

    2015223