Title of article :
Determination of local density and effective atomic number by the dual-energy computerized tomography method with the 192Ir radioisotope
Author/Authors :
Rizescu، نويسنده , , Costel and Be?liu، نويسنده , , C?lin and Jipa، نويسنده , , Alexandru، نويسنده ,
Abstract :
This paper presents the theoretical and experimental results obtained at the Research Institute for Electrical Engineering, Bucharest, Romania, in determining local density and effective atomic number by a newly developed CT method using dual-energy gamma radiation from the 192Ir radioisotope. The applied method is based on modeling total effective cross-section of gamma radiation in the natural materials in function of the atomic number (Z from 1 to 92), in terms of the photoelectric and Compton cross-sections. Also, a new parameter (composition factor k) given by the ratio of the linear attenuation coefficients from the two tomograms is introduced. We investigated 16 materials with effective atomic number Zeff between 6 and 72.2 and bulk density ranging from 2.15 to 10.51 g/cm3, using 310.5 and 469.1 keV gamma radiation. Our results show very good accuracy of the dual-energy CT method for most materials. The error in determining the effective atomic number is less than 5% for Zeff>25 and less than 10% for light materials (Zeff<15), while the error in density estimation is always smaller than 3%.
Keywords :
Gamma Ray , 192-iridium source , tomography , Dual-energy CT method
Journal title :
Astroparticle Physics