• Title of article

    Ceramics high rate timing RPC

  • Author/Authors

    Naumann، نويسنده , , L. and Kotte، نويسنده , , Patrick R. and Stach، نويسنده , , D. and Wüstenfeld، نويسنده , , J.، نويسنده ,

  • Pages
    4
  • From page
    138
  • To page
    141
  • Abstract
    A resistive plate counter for timing purposes in the high rate environment of the Compressed Baryonic Matter Experiment has been developed at the Forschungszentrum Dresden-Rossendorf. The detector electrodes are made of a ceramics composite whose volume resistivity can be tuned in the production process over five orders of magnitude. The detector prototype has been tested with single electrons of 32 MeV. It shows an all-time high rate capability for electron fluxes up to 5×105 s−1 cm−2.
  • Keywords
    Ceramics composite , Time resolution , Detection efficiency , Bulk resistivity , Rate capability , RPC
  • Journal title
    Astroparticle Physics
  • Record number

    2015622