Title of article :
Performance of the CAPRICE98 balloon-borne gas-RICH detector
Author/Authors :
Bergstrِm، نويسنده , , D. and Boezio، نويسنده , , M. and Carlson، نويسنده , , P. and Francke، نويسنده , , T. and Grinstein، نويسنده , , S. and Weber، نويسنده , , Felix N. and Suffert، نويسنده , , M. and Hof، نويسنده , , M. J. Kremer، نويسنده , , J. and Menn، نويسنده , , W. and Simon، نويسنده , , Saba M. and Stephens، نويسنده , , S.A. and Ambriola، نويسنده , , M. and Bellotti، نويسنده , , R. and Cafagna، نويسنده , , F. and Castellano، نويسنده , , M. and Ciacio، نويسنده , , F. and Circella، نويسنده , , M. di Marzo، نويسنده , , M.P.De and Finetti، نويسنده , , N. and Papini، نويسنده , , P. and Piccardi، نويسنده , , S. and Spillantini، نويسنده , , P. and Bartalucci، نويسنده , , S. and Ricci، نويسنده , , M. and Bidoli، نويسنده , , V. and Casolino، نويسنده , , M. and Pascale، نويسنده , , M.P.De and Morselli، نويسنده , , A. and Picozza، نويسنده , , P. and Sparvoli، نويسنده , , R. and Barbiellini، نويسنده , , G. and Schiavon، نويسنده , , P. and Vacchi، نويسنده , , A. and Zampa، نويسنده , , N. and Mitchell، نويسنده , , J.W. and Ormes، نويسنده , , J.F. and Streitmatter، نويسنده , , R.E. and Bravar، نويسنده , , U. and Stochaj، نويسنده , , S.J.، نويسنده ,
Pages :
14
From page :
161
To page :
174
Abstract :
A RICH counter using a gas radiator of C4F10 and a photosensitive MWPC with pad readout has been developed, tested in particle beam at CERN and used in the CAPRICE98 balloon-borne experiment. The MWPC was operated with a TMAE and ethane mixture at atmospheric pressure and used a cathode pad plane to give an unambiguous image of the Cherenkov light. The induced signals in the pad plane were read out using the AMPLEX chip and CRAMS. The good efficiency of the Cherenkov light collection, the efficient detection of the weak signal from single UV photons together with a low noise level in the electronics of the RICH detector, resulted in a large number of detected photoelectrons per event. For β≃1 charge one particles, an average of 12 photoelectrons per event were detected. The reconstructed Cherenkov angle of 50 mrad for a β≃1 particle had a resolution of 1.2 mrad (rms). The RICH was flown with the CAPRICE98 magnetic spectrometer and was the first RICH counter ever used in a balloon-borne experiment capable of identifying charge one particles at energies above 5 GeV. The RICH provided an identification of cosmic ray antiprotons up to the highest energies ever studied (about 50 GeV of total energy). The spectrometer was flown on 28–29 May 1998 from Fort Sumner, New Mexico, USA.
Keywords :
Cosmic rays , Balloon instrumentation , Cherenkov detector
Journal title :
Astroparticle Physics
Record number :
2015683
Link To Document :
بازگشت