Title of article
Performance of the liquid xenon detector for the MEG experiment
Author/Authors
Nishimura، نويسنده , , Yasuhiro and Natori، نويسنده , , Hiroaki، نويسنده ,
Pages
5
From page
376
To page
380
Abstract
A 900-l liquid xenon (LXe) detector was constructed for the MEG experiment to look for μ + → e + γ . With proper calibration and monitoring the detector was successfully operated during the first physics data taking for three months in 2008. We evaluated the performance of the LXe detector around the signal- γ energy of 52.8 MeV by using 54.9-MeV photons obtained from π 0 decays.
Keywords
Liquid xenon scintillator , Lepton flavor violation
Journal title
Astroparticle Physics
Record number
2015698
Link To Document