Title of article
Stability of Gd-loaded liquid scintillator for reactor neutrino detection
Author/Authors
Katsumata، نويسنده , , M. and Miyata، نويسنده , , H. and Tamura، نويسنده , , N. and Kawasaki، نويسنده , , T.، نويسنده ,
Pages
7
From page
50
To page
56
Abstract
Gd-loaded liquid scintillators are promising tools for detection of anti-electron neutrinos, yet their stability remains a concern for neutrino experiments. This study investigated the instability of a Gd-loaded liquid scintillator and found that Gd precipitated and light yield decreased due to oxidation. The precipitation not only reduced transmission but also decreased the Gd concentration. However, when the antioxidant 2,6-di-tert-butyl-4-methylphenol (BHT) was added to the liquid scintillator, we obtained a stable liquid scintillator at room temperature.
Keywords
Neutrino , BC521 , Reactor , Liquid scintillator , gD
Journal title
Astroparticle Physics
Record number
2015746
Link To Document