Title of article :
Test of the wire ageing induced by radiation for the CMS barrel muon chambers
Author/Authors :
Conti، نويسنده , , E. and Gasparini، نويسنده , , F.، نويسنده ,
Pages :
10
From page :
472
To page :
481
Abstract :
We have carried out laboratory tests to measure the ageing of a wire tube due to pollutants outgassed by various materials. The tested materials are those used in the barrel muon drift tubes of the CMS experiment at LHC. An X-ray gun irradiated the test tube to accelerate the ageing process. No ageing effect has been measured for a period equivalent to 10 years of operation at LHC.
Keywords :
ageing , Wire chamber
Journal title :
Astroparticle Physics
Record number :
2016025
Link To Document :