Title of article :
Low background germanium planar detector for gamma-ray spectrometry
Author/Authors :
Loaiza، نويسنده , , P. and Chassaing، نويسنده , , C. and Hubert، نويسنده , , Ph. and Nachab، نويسنده , , A. and Perrot، نويسنده , , F. and Reyss، نويسنده , , J.-L. and Warot، نويسنده , , G.، نويسنده ,
Pages :
7
From page :
64
To page :
70
Abstract :
A new ultra-low background planar germanium spectrometer has been developed. The planar geometry improves the sensitivity and energy resolution below 600 keV. The integral background counting rate in the Laboratoire Souterrain de Modane (4800 m water equivalent) in the energy range from 20 to 1500 keV for the planar Ge (mass=800 g) is 140 count/day. After 40 days of statistics, the background counting rates for all expected single lines are below 0.5 count/day with the exception of 210Pb(46-keV line) which was measured to be (1.76±0.25) count/day. Monte Carlo simulations have been performed to explain the origin of the remaining background and to calculate the detection efficiencies. Sensitivities around 1 mBq/kg are obtained within few days of statistics for 226Ra and 228Th. The main achievement is the high sensitivities for 210Pb (46-keV line) and 238U (234Th: 63 and 93 keV lines). For an aluminium sample (mass=1 kg) the limits obtained in 15 days are 210 Pb < 9 mBq / kg and 238 U < 3 mBq / kg .
Keywords :
Low-background , Monte Carlo simulation , gamma-ray spectrometry
Journal title :
Astroparticle Physics
Record number :
2016242
Link To Document :
بازگشت