• Title of article

    Measurement of resonance modes causative of beam position monitor signal noise in vacuum chamber of storage ring

  • Author/Authors

    Joo، نويسنده , , Youngdo and Hwang، نويسنده , , Ilmoon and Park، نويسنده , , Sungju and Kim، نويسنده , , Changbum، نويسنده ,

  • Pages
    4
  • From page
    11
  • To page
    14
  • Abstract
    It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S21) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.
  • Keywords
    Beam position monitor , Transverse electric mode , Vacuum chamber , Pohang Light Source
  • Journal title
    Astroparticle Physics
  • Record number

    2016385